Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	21
Date	08/07/14
Start Time	15:37:10
Diameter Midpoint
 11.3	1480.24
 11.8	2265.15
 12.2	3287.54
 12.6	4228.59
 13.1	6480.53
 13.6	7198.37
 14.1	12346.5
 14.6	15108.3
 15.1	18999.3
 15.7	25639.7
 16.3	34315.7
 16.8	44626.7
 17.5	56407.7
 18.1	67928.5
 18.8	85667.7
 19.5	102567
 20.2	124308
 20.9	140769
 21.7	164376
 22.5	191566
 23.3	219705
 24.1	255086
 25.0	291276
 25.9	327620
 26.9	371113
 27.9	410657
 28.9	454473
 30.0	499887
 31.1	554371
 32.2	605441
 33.4	653025
 34.6	701798
 35.9	753835
 37.2	808063
 38.5	849894
 40.0	887170
 41.4	913259
 42.9	928751
 44.5	932488
 46.1	945164
 47.8	932657
 49.6	934086
 51.4	916176
 53.3	883744
 55.2	838389
 57.3	795393
 59.4	749439
 61.5	693935
 63.8	632133
 66.1	564742
 68.5	499409
 71.0	432090
 73.7	368387
 76.4	308196
 79.1	253463
 82.0	204065
 85.1	163302
 88.2	128352
 91.4	98973.2
 94.7	75369.4
 98.2	56728.2
101.8	42115.7
105.5	30679
109.4	22093.7
113.4	16329
117.6	11333.5
121.9	8357.05
126.3	5872.28
131.0	4120.36
135.8	3042.4
140.7	2283.58
145.9	1706.47
151.2	1254.92
156.8	985.921
162.5	698.407
168.5	564.497
174.7	481.065
181.1	361.683
187.7	310.61
194.6	268.485
201.7	222.608
209.1	264.318
216.7	166.887
224.7	149.518
232.9	183.22
241.4	143.621
250.3	125.311
259.5	161.25
269.0	147.192
278.8	128.244
289.0	126.739
299.6	114.625
310.6	74.7491
322.0	63.1661
333.8	92.296
346.0	51.3303
358.7	63.2052
371.8	72.679
385.4	51.3555
399.5	57.2262
414.2	33.5305
429.4	41.3135
445.1	30.1113
461.4	29.1225
478.3	23.7162
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.7182
High Voltage	9922.73
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	44.5521
Mean(nm)	46.7118
Geo. Mean(nm)	43.7818
Mode(nm)	46.1384
Geo. Std. Dev.	1.43985
Total Concentration(#/cm)	2.41571e+007
Comment	